TECHNICAL

F1.H

GENERAL
Durable corrosion resistant construction specifically for outdoor use.

Heat input 12kW (41,000 BTU/h).

Gas type: Natural Gas or bulk LPG.

Flame protection by 100% shut off thermo electric valve.

Ignition of pilot by piezo igniter.

These units require brackets for support and need to be installed (brackets supplied as an accessory.

LOCATION & COVERAGE
A single heater will provide warmth with a diameter of up to 6 metres, depending on weather conditions. Maintaining a comfort level in a sheltered area is easier than in an exposed area. If possible locate heaters in places sheltered from winds, near buildings, walls, fences etc.

Groups of heaters can be used to heat large areas, positioning them to give overlapping heat patterns. This gives an all round radiant warmth for even greater comfort.

LOCATION HEATER SPACING
Well shielded areas, mild climate Up to 6m
Shielded 2 sides, average climate 4.25m
Little shielding, cool climate 3m
Exposed, cold climate 2.5m

ACCESSORIES & OPTIONS
Burner Cover Bag. For winter protection.

Wall and Ceiling Brackets. Designed and supplied to customer specification.

Extended Guarantee. Available

IMPORTANT – SAFETY
Combustible Materials. Heaters must be located such that the indicated safety clearance distances from combustible materials are ensured.

Gas supply pipework must always be installed in accordance with local codes of practice and a gas isolating valve fitted in the supply to each heater.

Refer to the manufacturer’s Assembly and Use Instructions for further information.

Designed for outdoor use only, with adequate high and low level ventilation.

SAFETY CLEARANCE DISTANCES